smartctl 5.43 2012-06-30 r3573 [i686-w64-mingw32-win7(64)-sp1] (sf-5.43-1) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint F2 EG Device Model: SAMSUNG HD502HI Serial Number: S1VZJ9DSA03906 LU WWN Device Id: 5 0024e9 2011e4810 Firmware Version: 1AG01118 User Capacity: 500 106 780 160 bytes [500 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3b Local Time is: Fri Apr 22 18:44:10 2016 SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 6307) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 106) minutes. Conveyance self-test routine recommended polling time: ( 12) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 093 093 011 Pre-fail Always - 3030 4 Start_Stop_Count 0x0032 094 094 000 Old_age Always - 6562 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 4 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 10211 9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 18776 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 6537 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 073 063 000 Old_age Always - 27 (Min/Max 13/27) 194 Temperature_Celsius 0x0022 071 062 000 Old_age Always - 29 (Min/Max 13/29) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 38770365 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 4 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 12 200 Multi_Zone_Error_Rate 0x000a 100 099 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Conveyance offline Completed without error 00% 18492 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.